Shelly Plus Addon Add-on (accessory/actuator for the entire Plus series) is a next-generation sensor that allows the connection of an infinite number of tools. Through a single device, you can connect up to 5 DS18B20 temperature probes or a DHT22 sensor for monitoring temperature and humidity.
Designed to simplify installation, it can be attached using clips on the desired Plus module. Various sensors and actuators can be connected: temperature, humidity, motion, brightness, etc.
Shelly Plus Add-on is a galvanically separated sensor interface for all Shelly Plus devices. You must have any device from the Shelly Plus family.
Device equipped with Wifi. No HUB is required for smartphone management.
It has both analog and digital input.
Compatibility: Shelly Plus Add-On is compatible with Amazon Alexa, Google Home, Samsung SmartThings, Android, and iOS.
It features both analog and digital inputs, so by connecting it with various sensors you can:
» Know the real-time status of your garage door.
» Measure precise temperature inside the aquarium or environment.
» Automatically raise/lower blinds based on room brightness.
» Automatically close outdoor blinds to protect them from wind.
Technical Specifications:
Size (HxWxD): 37 x 42 x 15 ±0.5 mm
Weight: 105 g / 3.70 ounces
Conductor cross section: maximum 1 mm²/17 AWG
Conductor stripped length: 4.5 mm/0.18 inches
Ambient temperature: From -20 °C to 40 °C / from -5 °F to 105 °F
Humidity: From 30% to 70% relative humidity
Max. altitude: 2000 meters / 6562 feet
Waterproof rating: IP20
AC power supply voltage: N/A
DC power supply voltage: 3.3 V (from the Shelly plus device)
Power consumption: < 0.5 W (without sensors)
Max. DC current: 10mA
VREF OUTPUT max. current: 1mA
VREF+R1 OUT resistance 10 kΩ
Shelly Plus device firmware functionality
Devices supporting the Shelly Plus add-on:
Shelly Plus 13:00
Shelly Plus 14:00
Shelly Plus i4/i4DC
Temperature reading: Depends on DS18B20 or DHT22 sensors
Humidity reading: Depends on DHT22 sensor
Digital input: From -15 V to 0.5 V (true)/from 2.5 V to 15 V (false)*
Analog input range: From 0 to 100%
Analog input reporting threshold: 1%**
Voltmeter range: from 0 to 10 V
Voltmeter reporting threshold: 0.1 V**
Analog/voltmeter input accuracy Better than ±5%